Fiber Termination - FC/PC (PT): FC/PC has good insertion repeatability, therefore is often used in single-mode fiber applications. Features a key for polarization-maintaining fiber installations.
Rent a high-performance laser for a time-limited experiment. Or try several laser options before deciding, which to choose.
Your request has been sent successfully. We'll get back to you as soon as possible.
Back to homepageBegin your product purchase process, with flexibility for customization based on your needs.
Your request has been sent successfully. We'll get back to you as soon as possible.
Back to homepageParameter | Minimum Value | Typical Value | Maximum Value |
---|---|---|---|
 Central wavelength, nm | 1300 | 1310 | 1320 |
 Longitudinal modes | - | multimode | - |
 Spectral line width FWHM, nm | - | 10 | 15 |
 Output power, mW 1 | - | 60 | - |
 Power stability, % (RMS, 8 hrs) 2 | - | 1 | 2 |
 Power stability, % (peak-to-peak, 8 hrs) 3 | - | 2 | 3 |
 Intensity noise, % (RMS, 20 Hz to 20 MHz) 4 | - | 0.2 | 1 |
 Transversal modes | - | TEM00 | - |
 Polarization direction | - | Aligned within the slow axis of the PM fiber and the key position. | - |
 Polarization extinction ratio (from PM fiber), dB | 20 | 23 | - |
 Control interface type 5 | - | UART | - |
 Operation mode | - | APC (CW) | - |
 Modulation bandwidth, MHz 6 | - | on request | - |
 Input voltage, VDC | 4.8 | 5 | 5.3 |
 External power supply requirement | - | +5 V DC, 5 A | - |
 Dimensions (WxDxH), mm 7 | - | 50 x 30 x 18 | - |
 Heat-sinking requirement, °C/W | - | 1 | - |
 Optimum heatsink temperature, °C | 15 | 20 | 30 |
 Warm up time, mins (cold start) | 0.2 | 1 | 2 |
 Temperature stabilization | - | Internal TEC | - |
 Overheat protection | - | Yes | - |
 Storage temperature, °C (non-condensing) | -10 | - | 50 |
 Net weight, kg | 0.1 | 0.12 | 0.14 |
 Max. power consumption, W | 5 | 10 | 20 |
 Warranty, months (op. hrs) 8 | - | 14 (10000) | - |
 RoHS | - | Yes | - |
 CE compliance | - | - General Product Safety Directive (GPSD) 2001/95/EC - (EMC) Directive 2004/108/EC |
- |
 Laser safety class | - | 3B | - |
 OEM lasers are not compliant with | - | IEC60825-1:2014 (compliant using additional accessories) | - |
 Country of origin | - | Lithuania | - |
1 The optical power can be tuned from virtually 0% to 100%. However, other specifications, such as central wavelength, power stability, noise, polarization ratio are not guaranteed at power levels other than factory preset power.
2 The long term power test is carried out at constant laser body temperature (+/-0.1 °C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.
3 The long term power test is carried out at constant laser body temperature (+/-0.1 °C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.
4 Noise level is measured with a fast photodiode connected to an oscilloscope. The overall system bandwidth is from 2 kHz to 20 MHz.
5 Break-out-boxes AM-C8 and AM-C3 can be used for conversion of UART communication to either USB or RS232.
6 TTL digital modulation up to 10 MHz could be implemented on request
7 Excluding control interface pins and an output window/fiber assembly.
8 Whichever occurs first. The laser has an integrated operational hours counter.
The key dimensions of a fiber-coupled MatchBox.
AM-BUNDLE2-EU
Standalone High-Performance Accessory Bundle
Fan Cooler for MatchBox®
USB Break-out-Box for Single-Wavelength MatchBoxⓇ
RS232 Break-out-Box for Single-Wavelength MatchBoxⓇ
AM-P7-EU
60W USB type C power supply
25W POWER SUPPLY (US or EU POWER CABLE)
Replacement Adapter for Coherent CUBE Type of Lasers
Replacement Adapter For Coherent OBIS Type of Lasers