Rent a high-performance laser for a time-limited experiment. Or try several laser options before deciding, which to choose.
Your request has been sent successfully. We'll get back to you as soon as possible.
Back to homepageBegin your product purchase process, with flexibility for customization based on your needs.
Your request has been sent successfully. We'll get back to you as soon as possible.
Back to homepageParameter | Minimum Value | Typical Value | Maximum Value |
---|---|---|---|
 Output power, mW 1 | - | 405 nm - 120 450 nm - 70 488 nm - 40 638 nm - 130 |
- |
 Wavelength tolerance, nm | 400 442 480 635 |
405 450 488 638 |
410 458 495 641 |
 Longitudinal modes | - | Multiple | - |
 Spectral line width FWHM, nm | - | 1 | 2 |
 Power stability, % (RMS, 8 hrs) 2 | - | 0.2 | 1 |
 Power stability, % (peak-to-peak, 8 hrs) | - | 1 | 3 |
 Intensity noise, % (RMS, 20 Hz to 20 MHz) 3 | - | 0.5 | 1 |
 Transversal modes | - | TEM00 | - |
 Polarization direction | - | Horizontal | - |
 Polarization contrast | 50 50 10 10 |
405 nm - 300 450 nm - 300 488 nm - 100 638 nm - 50 |
- |
 Beam height (1/e2), mm | - | 405 nm - 1.3 450 nm - 1.4 488 nm - 1.3 638 nm - 1.2 |
1.7 1.6 1.7 1.6 |
 Beam width (1/e2), mm | - | 405 nm - 0.9 450 nm - 0.9 488 nm - 0.8 638 nm - 1 |
1.4 1.3 1.1 1.3 |
 Beam position overlap, mm 4 | - | - | 1 |
 Horizontal beam divergence, mrad | - | 405 nm - 0.9 450 nm - 1.2 488 nm - 1.1 638 nm - 1.2 |
1.5 1.9 1.4 1.4 |
 Vertical beam divergence, mrad | - | 405 nm - 0.5 450 nm - 0.5 488 nm - 0.4 638 nm - 0.6 |
1 0.7 1.2 1 |
 M² effective | - | 405 nm - 1.3 450 nm - 1.4 488 nm - 1.3 638 nm - 1.3 |
1.5 1.6 1.5 1.4 |
 Control interface type 5 | - | UART | - |
 Operation mode | - | ACC (CW) | - |
 Modulation bandwidth, MHz 6 | - | 10 | - |
 Input voltage, VDC | 8 | 9 | 12 |
 External power supply requirement 7 | - | +9 V DC, 1.5 A | +12 V DC, 1.5 A |
 Dimensions (WxDxH), mm 8 | - | 50 x 30 x 18 | - |
 Beam height from the base, mm | - | 10.4 | - |
 Heat-sinking requirement, °C/W | - | <0.5 | - |
 Optimum heatsink temperature, °C | - | 25 | - |
 Warm up time, mins (cold start) | - | < 1 | 2 |
 Temperature stabilization | - | Internal TEC | - |
 Overheat protection | - | Yes | - |
 Storage temperature, °C (non-condensing) | -10 | - | 50 |
 Net weight, kg | - | 0.15 | - |
 Power consumption, W 9 | - | 2 | 18 |
 Warranty, months (op. hrs) 10 | - | 14 (10000) | - |
 RoHS | - | Yes | - |
 CE compliance | - | - General Product Safety Directive (GPSD) 2001/95/EC - (EMC) Directive 2004/108/EC | - |
 OEM lasers are not compliant with | - | IEC60825-1:2014 (compliant using additional accessories) | - |
1 The optical power can be tuned from virtually 0% to 100% by changing the driving current of the laser diodes. However, other specifications, such as central wavelength, power stability, noise, polarization ratio, beam shape, quality, and circularity are not guaranteed at power levels other than factory preset power. Significantly worse power stability is to be expected at very low power levels, e.g. <3% from specified nominal power.
2 The long term power test is carried out at constant laser body temperature (+/-0.1 °C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.
3 Noise level is measured with a fast photodiode connected to an oscilloscope. The overall system bandwidth is from 2 kHz to 20 MHz.
4 Measured at 1 m from output aperture between the centers of two most distant beams.
5 The break-out-box AM-C9 can be used for the conversion of UART communication to either USB.
6 TTL digital modulation up to 10 MHz.
7 If the break-out-box AM-C9 is used, a PD (Power Delivery) type of power supply can be used.
8 Excluding control interface pins and an output window/fiber assembly.
9 For single enabled wavelength.
10 Whichever occurs first.
MatchBox Wavelength combiner drawing
Flow cytometry is a sophisticated analytical technique widely used in biomedical research and clinical diagnostics. It allows for the simultaneous analysis of multiple physical and chemical characteristics of cells or particles as they flow through a laser beam. By utilizing fluorescence and light-scattering principles, flow cytometry provides valuable insights into cell populations, allowing researchers to study cell morphology, identify cell types, and assess various cellular functions with high-throughput precision.
Laser Combiner Accessory Bundle
USB Break-out-Box for Multi-Wavelength MatchBoxⓇ
18W USB type C power supply
60W USB type C power supply
Compact Fan Cooler For MatchBox®
Fan Cooler for MatchBox®
Compact TEC-Cooled Mounting Plate For MatchBox
MatchBoxⓇ Adapter For 25mm Post
MatchBox Laser Shutter for 16 mm Cage System
XZ Axis Adjustable Shutter With Internal SM05 Thread
Safety key box
Laser Safety Goggles for 200-400 nm, 765-1080 nm