Multi-Wavelength Laser

Item Code: 40A-48A-52A-64A-10-NT-NF
Diode Shaped beam
Filter
Preliminary
Product specifications are subject to change, delivery time is less predictable.
Full production
Product specifications are stable. Delivery time is predictable.
Replacement in due course
The product is to be replaced. Please contact us regarding forseeable changes
Not for new designs
The product is to be discontinued. Please contact us for production plans.
Orders still accepted, deliveries still possible
The product will be discontinued soon but we still have some stock of finished items or neccessary components.
No more orders accepted
Some products might be reserved for in-warranty replacement and outstanding orders.
Discontinued
The product is no longer available. Please contact us regarding alternatives or custom solutions.
Available (in stock) Not in stock

Description

Revolutionize your research in life sciences and fluorescence applications with our cutting-edge 4-Wavelength Laser Combiner. This compact powerhouse seamlessly integrates four distinct wavelengths into a single housing, providing unmatched convenience without sacrificing performance. Now available with custom beam shaping.

Features:
  • Four wavelengths
  • Plug-and-play
  • Single user interface for all 4 wavelengths
Advantages:
  • Space-saving design
  • No optics realignment
  • Remote PC control




Last edited on: 31 January 2024
Parameter Minimum Value Typical Value Maximum Value
 Output power, mW 1 - 405 nm - 120
488 nm - 40
520 nm - 80
638 nm - 130
-
 Wavelength tolerance, nm - +/-5 -
 Longitudinal modes - Multiple -
 Spectral line width FWHM, nm - 1 2
 Power stability, % (RMS, 8 hrs) at 20°C 2 - 0.2 1
 Power stability, % (peak-to-peak, 8 hrs) 3 - 1 3
 Intensity noise, % (RMS, 20 Hz to 20 MHz) 4 - 0.5 1
 Transversal modes - TEM00 -
 Polarization direction - Horizontal -
 Polarization contrast 405 nm - 50
488 nm - 50
520 nm - 50
638 nm - 10
405 nm - 300
488 nm - 400
520 nm - 300
638 nm - 100
-
 Beam diameter at aperture (1/e2), mm 0.7 1 1.5
 Beam position overlap, mm 0.1 0.3 0.5
 Beam divergence (full angle), mrad - 1.1 -
 M² effective (405 nm wavelength) 1.2 1.5 3
 M² effective (488 nm wavelength) 1.2 1.5 3
 M² effective (520 nm wavelength) 2 3 5
 M² effective (638 nm wavelength) 1.2 1.4 1.7
 Control interface type 5 - UART -
 Operation mode - ACC (CW) -
 Modulation bandwidth, MHz 6 - 10 -
 Input voltage, VDC - 9 12
 External power supply requirement 7 - +9 V DC, 1.5 A +12 V DC, 1.5 A
 Dimensions (WxDxH), mm 8 - 50 x 30 x 18 -
 Beam height from the base, mm - 10.4 -
 Heat-sinking requirement, °C/W - <0.5 -
 Optimum heatsink temperature, °C 15 20 30
 Warm up time, mins (cold start) 0.1 0.5 1
 Temperature stabilization - Internal TEC -
 Overheat protection - Yes -
 Storage temperature, °C (non-condensing) -10 - 50
 Net weight, kg - 0.3 -
 Power consumption, W 9 - 2 18
 Warranty, months (op. hrs) 10 - 14 (10000) -
 RoHS - Yes -
 CE compliance - - General Product Safety Directive (GPSD) 2001/95/EC - (EMC) Directive 2004/108/EC -
 OEM lasers are not compliant with - IEC60825-1:2014 (compliant using additional accessories) -

1 The optical power can be tuned from virtually 0% to 100% by changing the driving current of the laser diodes. However, other specifications, such as central wavelength, power stability, noise, polarization ratio, beam shape, quality, and circularity are not guaranteed at power levels other than factory preset power. Significantly worse power stability is to be expected at very low power levels, e.g. <3% from specified nominal power.

2 The long term power test is carried out at constant laser body temperature (+/-0.1 ‎°C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.

3 The long term power test is carried out at constant laser body temperature (+/-0.1 ‎°C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.

4 Noise level is measured with a fast photodiode connected to an oscilloscope. The overall system bandwidth is from 2 kHz to 20 MHz.

5 The break-out-box AM-C9 can be used for conversion of UART communication to USB.

6 TTL digital modulation up to 10 MHz.

7 If the break-out-box AM-C9 is used, a PD (Power Delivery) type of power supply can be used.

8 Excluding control interface pins and an output window/fiber assembly.

9 For single enabled wavelength.

10 Whichever occurs first.

Drawing

None

Drawing of Multi-Wavelength Laser